A Misleading Flow Cytometric Analysis of Dna in an Adenocarcinoma: A Comparative Flow Cytometric and Cytogenetic Study
Document Type
Article
Publication Date
1-1-1986
Description
A case is presented in which flow cytometric and cytogenetic analysis was done on a biopsy from a highly anaplastic metastatic adenocarcinoma. Flow cytometric analysis of DNA content failed to show a significant population of aneuploid cells. However, histologic examination revealed a substantial number of tumor cells, and cytogenetic analysis produced chromosome counts ranging from 20 to 144.
Citation Information
Lee, Greta M.; and Youngberg, George. 1986. A Misleading Flow Cytometric Analysis of Dna in an Adenocarcinoma: A Comparative Flow Cytometric and Cytogenetic Study. Journal of Surgical Oncology. Vol.31(4). 275-278. https://doi.org/10.1002/jso.2930310411 PMID: 3724183 ISSN: 0022-4790